Detail Information |
|||
| ISO Viscosity Grade: | 100 | Compliance Standard: | ISO 11158 L-HM; GB 11118.1 |
|---|---|---|---|
| Base Oil Type: | Mineral Oil | Product Type: | L-HL Anti-Rust Hydraulic Oil |
| Recommended Application: | Industrial Hydraulic Systems, Machine Tools, Cold Region Operation | Key Performance: | Oxidation Stability, Anti-Wear Protection, Rust And Corrosion Protection |
| Highlight: | L-HL 100 Hydraulic Oil,Machine Tool Lubrication L-HL Hydraulic Oil,ISO VG 100 Machine Tool Hydraulic Fluid |
||
Product Description
Great Wall L-HL 100 anti-rust oxidation hydraulic oil is blended from highly refined mineral base oils with anti-oxidation, rust-inhibition, defoamant and pour-point depressant additives. It is classified as ISO VG100 under ISO 3448 and as HL under ISO 11158 — a pure-mineral HH fluid with improved rust and oxidation protection. It can also be positioned to GB 11118.1 L-HL and SINOPEC/Great Wall Puli L-HL enterprise specs such as Q/SH 303 093.
The product is bright and clear with thick viscosity and strong film support. It is mainly intended for low-pressure hydraulic systems, machine-tool headstock and gearbox auxiliary lubrication, medium-speed and low-speed circulating loops, and general industrial rust-prevention circuits upgraded from high-viscosity machine oil.
- Thick film for medium/low speed: VG100 kinematic viscosity at 40℃ is 90–110 mm²/s, thicker than VG68, giving a more stable film for headstocks, gearbox auxiliary lubrication, medium-low speed circulation and heavy-film requirements.
- Strong oxidation stability: Total acid-number increase after 1000 h oxidation is not more than 2.0 mgKOH/g, suppressing sludge and acid rise and extending drain intervals versus general full-loss machine oil.
- Outstanding rust and corrosion control: Copper corrosion 100℃*3 h not more than class 1; rust prevention Procedure A 24 h no rust — protecting steel, copper and other metals in humid storage and between-process service.
- Good demulsibility: Fast water separation at 54℃, reference not more than 30 min, reducing valve sticking and filter blockage from emulsification.
- Balanced air release and foam control: Air release at 50℃ not more than 15 min; foam sequences I/II/III 150/0, 75/0, 150/0 mL, lowering cavitation, noise and sluggish response.
- Seal compatibility: Evaluated for seal compatibility per SH/T 0305 and common NBR/standard elastomers, reducing leakage and swelling risk.
| Item | Specification / Reference | Note |
|---|---|---|
| ISO VG | 100 | ISO 3448 grade |
| Kinematic viscosity 40℃ | 90.0–110 mm²/s | GB L-HL and ISO HL band |
| Kinematic viscosity 0℃ | ≤2560 mm²/s | ISO 11158 HL cold pump-suction reference |
| Kinematic viscosity 100℃ | ≥9.90 mm²/s | High-temp retention reference (ISO HL) |
| Viscosity index | ≥80, report | GB minimum 80 |
| Pour point | ≤-6℃ delivery; lower pour by agreement | GB L-HL100 pour ≤-6 |
| Flash point COC | ≥205℃ | GB/ISO L-HL100 minimum |
| Recommended oil temperature | About 10–70℃ system temperature (per pump maker) | Thick grade, medium temp, medium/low speed |
| Suitable duty | Normal to medium temp, medium/low speed, thick film/circulation | Headstock, gearbox auxiliary, low-pressure units |
| Indicator | Rating | Visualization |
|---|---|---|
| Thick film / medium-low speed support | Very good | |
| Oxidation stability | Very good | |
| Rust & corrosion control | Excellent | |
| Demulsibility / water separation (54℃) | Good | |
| Air release (50℃) | Moderate | |
| Foam resistance (I/II/III) | Good | |
| Cold pump suction (0℃) | Weak | |
| Elastomer compatibility | Excellent |
Ratings are for storefront display only: █ excellent/very good, ░ good. VG100 strengths are thick film, medium-low speed circulation and general rust control. Do not prioritize it for cold outdoor start-up or high-pressure piston/vane heavy-wear service — use L-HV for low temperature and L-HM for high pressure.
| Item | Requirement / Typical | Method |
|---|---|---|
| Appearance | Bright, clear | Visual |
| Kinematic viscosity 40℃ | 90.0–110 mm²/s | GB/T 265 / ISO 3104 |
| Kinematic viscosity 0℃ | ≤2560 mm²/s (reference) | ISO 3104 (ISO HL) |
| Kinematic viscosity 100℃ | ≥9.90 mm²/s (reference) | ISO 3104 (ISO HL) |
| Viscosity index | ≥80, report | GB/T 1995/2541 / ISO 2909 |
| Flash point COC | ≥205℃ | GB/T 3536 / ISO 2592 |
| Pour point | ≤-6℃; lower pour by agreement | GB/T 3535 / ISO 3016 |
| Water | Trace / ≤0.025% or ≤250 mg/kg | GB/T 260 / ISO 6296 |
| Copper corrosion 100℃*3h | ≤class 1 | GB/T 5096 / ISO 2160 |
| Rust prevention A, 24h | No rust / pass | GB/T 11143 / ISO 7120 |
| Demulsibility 54℃ to 3 mL emulsion | ≤30 min | GB/T 7305 / ISO 6614 |
| Foam sequences I/II/III | 150/0, 75/0, 150/0 mL | GB/T 12579 / ISO 6247 |
| Air release 50℃ | ≤15 min | SH/T 0308 / ISO 9120 |
| Seal compatibility index | Report (no fixed GB L-HL100 limit; per agreement) | SH/T 0305 |
| Oxidation 1000h acid-number increase | ≤2.0 mgKOH/g | GB/T 12581 |
| Mechanical impurities | None / report | GB/T 511 |
- Low-pressure hydraulic systems: under the general L-HL position, machine-tool low-pressure gear pumps and medium-low speed light-to-medium duty hydraulic drives.
- Machine-tool headstocks, gearbox auxiliary lubrication, medium-low speed circulating oil loops and bearing-housing general rust-prevention lubrication.
- Upgrades from high-viscosity machine oil where better oxidation and rust protection are required, e.g. general industrial circulation circuits.
- Not recommended as first choice for high-pressure piston/vane pumps with severe wear risk, frequent outdoor cold start-up, silver-containing precision systems without confirmed corrosion data, or heavy-duty main circuits. Use L-HM for high pressure and L-HV for low temperature.
- Do not mix with anti-wear hydraulic oils, gear oils or unknown brands. Flush the tank before changeover, remove residual oil and sludge, and filter to the target cleanliness.
- Refill through a dedicated filtration trolley; agree ISO 4406 cleanliness with system requirement. Thick VG100 filters more slowly than lower grades, so allow extra filtration time.
- Store in a cool, dry place with protection from water, moisture, dust and mechanical impurities. L-HL series can be supplied in 170 kg steel drums, subject to actual offer.
- Before first fill, verify pump-allowed start-up viscosity, operating viscosity and maximum system oil temperature. Use L-HL mainly for low-pressure, normal-to-medium temperature, medium-low speed light/medium duty, with maximum service temperature reference about 80℃.
Disclaimer: This copy is a general storefront draft. GB 11118.1 L-HL limits are cited from the national-standard L-HL table; third-party L-HL100 sheets are used only for cross-check. All VG100 typical values, adopted pour-point basis, air-release/anti-emulsion limits and commercial availability must be confirmed against the latest SINOPEC/Great Wall official TDS and batch COA before listing or contracting. Great Wall.