Great Wall L-HM 100 Anti Wear Hydraulic Oil with Oxidation Stability and Demulsibility
Product Details:
| Place of Origin: | Chian |
| Brand Name: | 10 drums |
| Certification: | ISO 3448 GB /11118.1 |
| Model Number: | Great Wall L-HM 100 |
Payment & Shipping Terms:
| Minimum Order Quantity: | 10 drums |
|---|---|
| Price: | Get Latest Quotation |
| Packaging Details: | 4drums per pallet, stretch film wrapped |
| Delivery Time: | 5-8 business days after receipt of deposit |
| Payment Terms: | L/C,D/A,D/P,T/T |
| Supply Ability: | Up to 50 metric tons per week |
|
Detail Information |
|||
| Compliance Standard: | ISO 11158 L-HM; Denison HF-0; Vickers I-286-S / M-2950; Cincinnati P-68 / P-69; GB 11118.1 | Recommended Application: | Industrial Hydraulic Systems, Mobile Machinery, Cold Region Operation |
|---|---|---|---|
| Base Oil Type: | Mineral Oil | ISO Viscosity Grade: | 100 |
| Product Type: | L-HM Anti-Wear Hydraulic Oil | Key Performance: | Oxidation Stability, Anti-Wear Protection, Rust And Corrosion Protection |
| Highlight: | L-HM 100 Hydraulic Oil,Heavy Load Film Hydraulic Oil,Heavy Load Film Hydraulic Fluid |
||
Product Description
Great Wall L-HM 100 anti-wear hydraulic oil is classified as ISO VG100 under ISO 3448 and as HM under ISO 11158, and can be positioned to GB 11118.1 L-HM. By pressure and chemistry it is offered as standard anti-wear, high-pressure zinc-type and high-pressure ashless: the standard grade serves industrial low-to-medium pressure high-viscosity circuits; the high-pressure zinc grade serves construction, mining, metallurgy, injection-molding and press systems with vane, piston and gear pumps; the ashless grade serves systems with copper, silver, silver-plated parts and precision valves.
VG100 is more viscous than VG46/68, giving a thicker film, better seal compensation and stronger protection for heavy-load, warm-shop, older and medium-to-high pressure mobile systems; because of higher cold-start viscosity, extremely low temperature service should use L-HV/L-HS or follow the pump-maker cold-viscosity window.
- Wear reduction: An anti-wear additive system is evaluated by four-ball wear, FZG/gear-machine load and vane-pump 100h tests to reduce wear on pumps, spools, cylinders and gear sets; high-pressure grades can attach multi-pump/OEM data, standard grades are positioned for low/medium pressure anti-wear use.
- Heavy-load film: VG100 kinematic viscosity at 40℃ in the 90–110 mm²/s band supports film thickness and leakage control in high-temperature, large-clearance and heavy-load systems.
- Oxidation stability: Suppresses sludge, varnish and acid build-up; standard/long-life grades can report oxidation to acid number 2.0 mgKOH/g for 1000h or longer, high-pressure/ashless grades follow longer-cycle TDS to reduce filter and servo-valve contamination.
- Rust and corrosion control: Copper corrosion 100℃*3h not more than class 1; rust prevention Procedure A distilled water no rust, high-pressure grades may report Procedure B synthetic seawater, ashless grades are friendlier to copper and silver systems.
- Demulsibility: Reported at 54℃ or 82℃ to 40-37-3, reference not more than 30 min depending on system water temperature; quickly removes entrained water to reduce valve sticking, filter blockage and emulsion wear.
- Air release and foam control: Foam sequences reported by grade, e.g. 150/0, 75/0, 150/0 or 150/10 depending on product; air release at 50℃ reported by grade—VG100 usually longer than VG32/46, high-pressure grades selected per pump cleanliness and defoam requirements.
- Seal and material compatibility: Evaluated by SH/T 0305 with NBR and common elastomers; do not use zinc standard/zinc HP in silver or OEM zinc-prohibited systems—use ashless.
| Item | Standard AW Reference | High-Pressure Zinc Reference | High-Pressure Ashless Reference | Note |
|---|---|---|---|---|
| ISO VG | 100 | 100 | 100 | ISO 3448 grade |
| Kinematic viscosity 40℃ | 90–110 mm²/s; industry band | 90–110 mm²/s; third-party HP typical 101.3 | Per Great Wall ashless VG100 TDS | GB/industry L-HM100 band |
| Kinematic viscosity 100℃ | Report; mineral VG100 reference about 10–11 | Third-party HP report | Per TDS | High-temp retention reference |
| Viscosity index | Standard ≥95 | Third-party HP 100 typical 105 | Ashless VG100 per TDS, can be ≥95 | Better VI for HP/ashless |
| Flash point COC | Industry standard lower limit reference ≥205℃; actual per TDS | Third-party HP 100 typical 245℃ | Per Great Wall TDS | COC method |
| Pour point | Industry standard can be ≤−9℃; long-life/HP reference ≤−17℃ | Third-party HP 100 typical −17℃ | Ashless VG100 per TDS; extreme cold use L-HV/L-HS | Cold start per pump window |
| Four-ball wear 392N/75℃/60min | Batch TDS/COA | Batch TDS/COA | Batch TDS/COA | SH/T 0189 |
| FZG/gear-machine fail stage | ≥10, report | ≥10, report | ≥10, report | SH/T 0306 |
| Vane pump 100h total loss | ≤100mg, report | Multi-pump/OEM bench report | Zinc-free pump bench report | SH/T 0307 / GB Annex A |
| Demulsibility 40-37-3 | 54℃ or 82℃ ≤30 min per system | Third-party 43-37-3/54℃ reference 21 min | Per TDS | GB/T 7305 |
| Air release 50℃ | Report by grade; VG100 usually longer than 32/46 | Third-party HP 100 reference 10 min | Per TDS | SH/T 0308 |
| Recommended pressure | Low/medium high-viscosity, heavy-film | Medium/high vane/piston/gear | Medium/high copper-silver precision | Silver: use ashless |
| Recommended oil temperature | About 15–60℃, per pump viscosity window | About 15–70℃, HP focus on cleanliness | About 15–70℃, focus on hydrolysis/water | Max temperature per equipment maker |
| Indicator | Standard | HP Zinc | HP Ashless | Visualization |
|---|---|---|---|---|
| Anti-wear / friction reduction | Good/very good | Very good/excellent | Very good/excellent | Std ████░ Zinc █████ Ashless █████ |
| Heavy-load film / leakage control | Very good | Very good | Very good | Std █████ Zinc █████ Ashless █████ |
| Oxidation stability | Good/very good | Very good | Very good | Std ████░ Zinc █████ Ashless █████ |
| Rust & corrosion control | Excellent | Excellent | Excellent (Cu/Ag friendlier) | Std █████ Zinc █████ Ashless █████ |
| Demulsibility 54/82℃ | Good (per system temp) | Very good | Very good | Std ████░ Zinc █████ Ashless █████ |
| Air release 50℃ | Report by grade | Good/very good | Good/very good | Std ███░░ Zinc ████░ Ashless ████░ |
| Foam I/II/III | By grade | By grade/excellent | By grade/excellent | Std ████░ Zinc █████ Ashless █████ |
| Filtration/cleanliness | Per agreement | Very good (HD) | Very good (ashless HD) | Std ███░░ Zinc █████ Ashless █████ |
| Elastomer compatibility | Excellent | Excellent | Excellent | Std █████ Zinc █████ Ashless █████ |
| Item | Requirement / Typical | Method |
|---|---|---|
| Appearance | Bright, clear | Visual |
| Kinematic viscosity 40℃ | 90–110 mm²/s; third-party HP typical 101.3, industry standard/HP band same | GB/T 265 / ISO 3104 |
| Kinematic viscosity 100℃ | Report; mineral VG100 reference about 10–11 | ISO 3104 |
| Viscosity index | Standard ≥95; third-party HP 100 typical 105 | GB/T 1995/2541 / ISO 2909 |
| Flash point COC | Industry standard lower-limit reference ≥205℃; third-party HP 100 typical 245℃; final per Great Wall TDS | GB/T 3536 / ISO 2592 |
| Pour point | Industry standard can be ≤−9℃; long-life/HP reference ≤−17℃; ashless per TDS | GB/T 3535 / ISO 3016 |
| Water | Trace / ≤0.025% | GB/T 260 / ISO 6296 |
| Mechanical impurities | None | GB/T 511 |
| Copper corrosion 100℃*3h | ≤class 1 (1a/1b per product) | GB/T 5096 / ISO 2160 |
| Rust prevention A/B, 24h | A distilled water no rust; HP may report B synthetic seawater no rust | GB/T 11143 / ISO 7120 |
| Demulsibility 40-37-3 | 54℃ or 82℃ ≤30 min per system; third-party HP 43-37-3/54℃ reference 21 min | GB/T 7305 / ISO 6614 |
| Foam sequences I/II/III | By grade, e.g. 150/0, 75/0, 150/0 or 150/10 | GB/T 12579 / ISO 6247 |
| Air release 50℃ | Report by grade; third-party HP 100 reference 10 min | SH/T 0308 / ISO 9120 |
| Four-ball wear 392N/75℃/60min | Batch TDS/COA | SH/T 0189 / NB/SH T 0189 |
| Gear-machine fail stage | ≥10 | SH/T 0306 |
| Vane pump 100h total loss | ≤100mg, report | SH/T 0307 / GB Annex A |
| Seal compatibility index | Batch TDS/COA | SH/T 0305 |
| Oxidation to acid 2.0mgKOH/g | Standard/long-life 1000h or longer; HP per TDS | GB/T 12581 |
| Rotary bomb 150℃ | HP/long-life per TDS; third-party HP 100 reference 310 min | SH/T 0193 |
| Hydrolytic stability (ashless/zinc-free HP) | Batch TDS/COA | SH/T 0301 |
| Cleanliness | Per supply agreement / ISO 4406; HD/ashless HD may report NAS/ISO | GB/T 14039, NAS 1638 |
- Standard L-HM100: Industrial low-to-medium pressure high-viscosity circuits, older hydraulic systems, warm-shop heavy-film service, and some medium-duty industrial gear auxiliaries only where the equipment maker permits hydraulic-oil use.
- High-pressure zinc L-HM100: Construction, building/mining, metallurgy, injection molding and press systems with medium-to-high pressure vane, piston and gear pumps; Denison HF-0, Eaton-Vickers and Cincinnati P68/P70/P69 apply only to the specific certified product.
- High-pressure ashless L-HM100: Systems with copper, silver, silver-plated parts and precision/servo valves; zinc-free formulation reduces copper/silver corrosion risk with hydrolytic stability and high cleanliness.
- Warm, heavy-load and low-speed heavy-service conditions: VG100 gives thicker film and better seal compensation, but verify pump cold-start viscosity; for northern winter outdoor cold start, validate low-temperature viscosity or use L-HV/L-HS.
- Not recommended as first choice for prolonged static service well below about −15℃ (use L-HV/L-HS), or for silver/sensitive-copper systems if a zinc standard/zinc HP grade is used without confirmation; do not mix different anti-wear chemistries without compatibility testing.
- Do not mix with other brands of anti-wear oil, gear oil or turbine oil; for zinc versus ashless systems, run compatibility and blend tests before mixing to avoid filterability, demulsibility and copper/silver corrosion issues.
- Flush tank and lines before changeover to remove sludge, water and contaminants; fill through a filtration trolley to the target ISO 4406/NAS cleanliness agreed with the pump maker, with stricter cleanliness for high-pressure servo/proportional systems.
- Store in a cool, dry place away from water, dust and metallic debris; supply formats such as 170 kg steel drum, 200 L drum or 16 L pails per actual offer.
- Before first fill, verify pump-allowed start-up viscosity, operating viscosity, maximum oil temperature and OEM approvals; for high-pressure service check anti-wear bench data, cleanliness, oxidation life and demulsibility/hydrolysis performance after water ingress.
Disclaimer: This copy is a general storefront draft. VG100 bandwidth, copper corrosion, rust, foam, vane-pump, gear-machine and oxidation references are from industry/third-party L-HM data; high-pressure VG100 air-release, demulsibility, VI, flash, pour and rotary bomb are from a third-party high-pressure sheet and used only as method/positioning references. Great Wall standard/HP-zinc/HP-ashless VG100 official typicals, pump-test results, OEM approvals and commercial availability must be confirmed against the latest SINOPEC/Great Wall official TDS and batch COA before listing or contracting.