• Great Wall L-HM 100 Anti Wear Hydraulic Oil with Oxidation Stability and Demulsibility
Great Wall L-HM 100 Anti Wear Hydraulic Oil with Oxidation Stability and Demulsibility

Great Wall L-HM 100 Anti Wear Hydraulic Oil with Oxidation Stability and Demulsibility

Product Details:

Place of Origin: Chian
Brand Name: 10 drums
Certification: ISO 3448 GB /11118.1
Model Number: Great Wall L-HM 100

Payment & Shipping Terms:

Minimum Order Quantity: 10 drums
Price: Get Latest Quotation
Packaging Details: 4drums per pallet, stretch film wrapped
Delivery Time: 5-8 business days after receipt of deposit
Payment Terms: L/C,D/A,D/P,T/T
Supply Ability: Up to 50 metric tons per week
Get Best Price Chat Now

Detail Information

Compliance Standard: ISO 11158 L-HM; Denison HF-0; Vickers I-286-S / M-2950; Cincinnati P-68 / P-69; GB 11118.1 Recommended Application: Industrial Hydraulic Systems, Mobile Machinery, Cold Region Operation
Base Oil Type: Mineral Oil ISO Viscosity Grade: 100
Product Type: L-HM Anti-Wear Hydraulic Oil Key Performance: Oxidation Stability, Anti-Wear Protection, Rust And Corrosion Protection
Highlight:

L-HM 100 Hydraulic Oil

,

Heavy Load Film Hydraulic Oil

,

Heavy Load Film Hydraulic Fluid

Product Description

Product Description

Great Wall L-HM 100 anti-wear hydraulic oil is classified as ISO VG100 under ISO 3448 and as HM under ISO 11158, and can be positioned to GB 11118.1 L-HM. By pressure and chemistry it is offered as standard anti-wear, high-pressure zinc-type and high-pressure ashless: the standard grade serves industrial low-to-medium pressure high-viscosity circuits; the high-pressure zinc grade serves construction, mining, metallurgy, injection-molding and press systems with vane, piston and gear pumps; the ashless grade serves systems with copper, silver, silver-plated parts and precision valves.

VG100 is more viscous than VG46/68, giving a thicker film, better seal compensation and stronger protection for heavy-load, warm-shop, older and medium-to-high pressure mobile systems; because of higher cold-start viscosity, extremely low temperature service should use L-HV/L-HS or follow the pump-maker cold-viscosity window.

Key Performance Benefits
  • Wear reduction: An anti-wear additive system is evaluated by four-ball wear, FZG/gear-machine load and vane-pump 100h tests to reduce wear on pumps, spools, cylinders and gear sets; high-pressure grades can attach multi-pump/OEM data, standard grades are positioned for low/medium pressure anti-wear use.
  • Heavy-load film: VG100 kinematic viscosity at 40℃ in the 90–110 mm²/s band supports film thickness and leakage control in high-temperature, large-clearance and heavy-load systems.
  • Oxidation stability: Suppresses sludge, varnish and acid build-up; standard/long-life grades can report oxidation to acid number 2.0 mgKOH/g for 1000h or longer, high-pressure/ashless grades follow longer-cycle TDS to reduce filter and servo-valve contamination.
  • Rust and corrosion control: Copper corrosion 100℃*3h not more than class 1; rust prevention Procedure A distilled water no rust, high-pressure grades may report Procedure B synthetic seawater, ashless grades are friendlier to copper and silver systems.
  • Demulsibility: Reported at 54℃ or 82℃ to 40-37-3, reference not more than 30 min depending on system water temperature; quickly removes entrained water to reduce valve sticking, filter blockage and emulsion wear.
  • Air release and foam control: Foam sequences reported by grade, e.g. 150/0, 75/0, 150/0 or 150/10 depending on product; air release at 50℃ reported by grade—VG100 usually longer than VG32/46, high-pressure grades selected per pump cleanliness and defoam requirements.
  • Seal and material compatibility: Evaluated by SH/T 0305 with NBR and common elastomers; do not use zinc standard/zinc HP in silver or OEM zinc-prohibited systems—use ashless.
VG100 Viscosity and Anti-wear Chart
Item Standard AW Reference High-Pressure Zinc Reference High-Pressure Ashless Reference Note
ISO VG 100 100 100 ISO 3448 grade
Kinematic viscosity 40℃ 90–110 mm²/s; industry band 90–110 mm²/s; third-party HP typical 101.3 Per Great Wall ashless VG100 TDS GB/industry L-HM100 band
Kinematic viscosity 100℃ Report; mineral VG100 reference about 10–11 Third-party HP report Per TDS High-temp retention reference
Viscosity index Standard ≥95 Third-party HP 100 typical 105 Ashless VG100 per TDS, can be ≥95 Better VI for HP/ashless
Flash point COC Industry standard lower limit reference ≥205℃; actual per TDS Third-party HP 100 typical 245℃ Per Great Wall TDS COC method
Pour point Industry standard can be ≤−9℃; long-life/HP reference ≤−17℃ Third-party HP 100 typical −17℃ Ashless VG100 per TDS; extreme cold use L-HV/L-HS Cold start per pump window
Four-ball wear 392N/75℃/60min Batch TDS/COA Batch TDS/COA Batch TDS/COA SH/T 0189
FZG/gear-machine fail stage ≥10, report ≥10, report ≥10, report SH/T 0306
Vane pump 100h total loss ≤100mg, report Multi-pump/OEM bench report Zinc-free pump bench report SH/T 0307 / GB Annex A
Demulsibility 40-37-3 54℃ or 82℃ ≤30 min per system Third-party 43-37-3/54℃ reference 21 min Per TDS GB/T 7305
Air release 50℃ Report by grade; VG100 usually longer than 32/46 Third-party HP 100 reference 10 min Per TDS SH/T 0308
Recommended pressure Low/medium high-viscosity, heavy-film Medium/high vane/piston/gear Medium/high copper-silver precision Silver: use ashless
Recommended oil temperature About 15–60℃, per pump viscosity window About 15–70℃, HP focus on cleanliness About 15–70℃, focus on hydrolysis/water Max temperature per equipment maker
VG100 Performance Chart
Indicator Standard HP Zinc HP Ashless Visualization
Anti-wear / friction reduction Good/very good Very good/excellent Very good/excellent Std ████░ Zinc █████ Ashless █████
Heavy-load film / leakage control Very good Very good Very good Std █████ Zinc █████ Ashless █████
Oxidation stability Good/very good Very good Very good Std ████░ Zinc █████ Ashless █████
Rust & corrosion control Excellent Excellent Excellent (Cu/Ag friendlier) Std █████ Zinc █████ Ashless █████
Demulsibility 54/82℃ Good (per system temp) Very good Very good Std ████░ Zinc █████ Ashless █████
Air release 50℃ Report by grade Good/very good Good/very good Std ███░░ Zinc ████░ Ashless ████░
Foam I/II/III By grade By grade/excellent By grade/excellent Std ████░ Zinc █████ Ashless █████
Filtration/cleanliness Per agreement Very good (HD) Very good (ashless HD) Std ███░░ Zinc █████ Ashless █████
Elastomer compatibility Excellent Excellent Excellent Std █████ Zinc █████ Ashless █████
Ratings are for storefront display only: █ excellent/very good, ░ good. VG100 strengths are heavy-load, warmer-duty, older-system and medium-to-high pressure mobile service with thicker film; for extremely low temperature use L-HV/L-HS, for silver/sensitive copper use ashless, and for ultra-high-pressure service select the certified OEM grade.
Product Quality Items
Item Requirement / Typical Method
Appearance Bright, clear Visual
Kinematic viscosity 40℃ 90–110 mm²/s; third-party HP typical 101.3, industry standard/HP band same GB/T 265 / ISO 3104
Kinematic viscosity 100℃ Report; mineral VG100 reference about 10–11 ISO 3104
Viscosity index Standard ≥95; third-party HP 100 typical 105 GB/T 1995/2541 / ISO 2909
Flash point COC Industry standard lower-limit reference ≥205℃; third-party HP 100 typical 245℃; final per Great Wall TDS GB/T 3536 / ISO 2592
Pour point Industry standard can be ≤−9℃; long-life/HP reference ≤−17℃; ashless per TDS GB/T 3535 / ISO 3016
Water Trace / ≤0.025% GB/T 260 / ISO 6296
Mechanical impurities None GB/T 511
Copper corrosion 100℃*3h ≤class 1 (1a/1b per product) GB/T 5096 / ISO 2160
Rust prevention A/B, 24h A distilled water no rust; HP may report B synthetic seawater no rust GB/T 11143 / ISO 7120
Demulsibility 40-37-3 54℃ or 82℃ ≤30 min per system; third-party HP 43-37-3/54℃ reference 21 min GB/T 7305 / ISO 6614
Foam sequences I/II/III By grade, e.g. 150/0, 75/0, 150/0 or 150/10 GB/T 12579 / ISO 6247
Air release 50℃ Report by grade; third-party HP 100 reference 10 min SH/T 0308 / ISO 9120
Four-ball wear 392N/75℃/60min Batch TDS/COA SH/T 0189 / NB/SH T 0189
Gear-machine fail stage ≥10 SH/T 0306
Vane pump 100h total loss ≤100mg, report SH/T 0307 / GB Annex A
Seal compatibility index Batch TDS/COA SH/T 0305
Oxidation to acid 2.0mgKOH/g Standard/long-life 1000h or longer; HP per TDS GB/T 12581
Rotary bomb 150℃ HP/long-life per TDS; third-party HP 100 reference 310 min SH/T 0193
Hydrolytic stability (ashless/zinc-free HP) Batch TDS/COA SH/T 0301
Cleanliness Per supply agreement / ISO 4406; HD/ashless HD may report NAS/ISO GB/T 14039, NAS 1638
Applications
  • Standard L-HM100: Industrial low-to-medium pressure high-viscosity circuits, older hydraulic systems, warm-shop heavy-film service, and some medium-duty industrial gear auxiliaries only where the equipment maker permits hydraulic-oil use.
  • High-pressure zinc L-HM100: Construction, building/mining, metallurgy, injection molding and press systems with medium-to-high pressure vane, piston and gear pumps; Denison HF-0, Eaton-Vickers and Cincinnati P68/P70/P69 apply only to the specific certified product.
  • High-pressure ashless L-HM100: Systems with copper, silver, silver-plated parts and precision/servo valves; zinc-free formulation reduces copper/silver corrosion risk with hydrolytic stability and high cleanliness.
  • Warm, heavy-load and low-speed heavy-service conditions: VG100 gives thicker film and better seal compensation, but verify pump cold-start viscosity; for northern winter outdoor cold start, validate low-temperature viscosity or use L-HV/L-HS.
  • Not recommended as first choice for prolonged static service well below about −15℃ (use L-HV/L-HS), or for silver/sensitive-copper systems if a zinc standard/zinc HP grade is used without confirmation; do not mix different anti-wear chemistries without compatibility testing.
Handling, Storage and Use
  • Do not mix with other brands of anti-wear oil, gear oil or turbine oil; for zinc versus ashless systems, run compatibility and blend tests before mixing to avoid filterability, demulsibility and copper/silver corrosion issues.
  • Flush tank and lines before changeover to remove sludge, water and contaminants; fill through a filtration trolley to the target ISO 4406/NAS cleanliness agreed with the pump maker, with stricter cleanliness for high-pressure servo/proportional systems.
  • Store in a cool, dry place away from water, dust and metallic debris; supply formats such as 170 kg steel drum, 200 L drum or 16 L pails per actual offer.
  • Before first fill, verify pump-allowed start-up viscosity, operating viscosity, maximum oil temperature and OEM approvals; for high-pressure service check anti-wear bench data, cleanliness, oxidation life and demulsibility/hydrolysis performance after water ingress.

Disclaimer: This copy is a general storefront draft. VG100 bandwidth, copper corrosion, rust, foam, vane-pump, gear-machine and oxidation references are from industry/third-party L-HM data; high-pressure VG100 air-release, demulsibility, VI, flash, pour and rotary bomb are from a third-party high-pressure sheet and used only as method/positioning references. Great Wall standard/HP-zinc/HP-ashless VG100 official typicals, pump-test results, OEM approvals and commercial availability must be confirmed against the latest SINOPEC/Great Wall official TDS and batch COA before listing or contracting.

Want to Know more details about this product
I am interested in Great Wall L-HM 100 Anti Wear Hydraulic Oil with Oxidation Stability and Demulsibility could you send me more details such as type, size, quantity, material, etc.
Thanks!