VG46 Fire Resistant Industrial Lubricant Oil Water Glycol HFC Hydraulic Fluid For Die Casting
Product Details:
| Place of Origin: | Zhuhai, Guangdong,Chian |
| Brand Name: | Shell |
| Certification: | ASTM |
| Model Number: | Shell Water-Glycol S2 CX 46 |
Payment & Shipping Terms:
| Minimum Order Quantity: | 10 drums |
|---|---|
| Price: | Get Latest Quotation |
| Packaging Details: | 4drums per pallet, stretch film wrapped |
| Delivery Time: | 5-8 business days after receipt of deposit |
| Payment Terms: | L/C,D/A,D/P,T/T |
| Supply Ability: | Up to 50 metric tons per week |
|
Detail Information |
|||
| Application: | Industrial Lubricant,neck Mold,die,Glass Mold,parison Mold | Type: | Greases,Compressor Oil,Chemical,32#,gear Oil Additive |
|---|---|---|---|
| Specification: | SAE,ACEA,Other,NSF,GB | General Composition: | Base Oil,Additives,Base Oil/additive,Yellow Oil,Special Application Oil |
| Product Name: | Sewing Machine Oil,Industrial Heavy-duty Gear Oil 150,Jinganwang,SKALN Model 100# High Temperature Industrial Chain Lubricant Oil,Lndustry Lubricant Oil | Color: | Brown,Yellow,clear And Transparent,white,Transparent |
| Packing: | 6PCS/Carton,Requirements,Customized,170KG /drum,200L Barrel | Form: | Liquid,Colloid,Factory-made,Semisolid |
| Quality: | Excellent,High Rank | Function: | Reduce Friction,Protect Gear,Increasing Lubricity |
| Appearance: | Oily Liquid,Transparent And Colorless Liquid,Brown Liquid,solid Lipid | Usage: | Lubrication And Maintain Sewing Machine And Related Equipement,machine Lubricant,Vessel,Car,fabric Embroidery |
| Packaging: | 200 L/ Iron Drum,flexitank/drum,200KG/ Iron Drum,50 L/ Barrel,50 KG/ Barrel | Volume: | 4L,200 Liter,100 ML,13L |
| Feature: | High Universality,High Flash Point Ignition | Keywords: | Hydraulic Oil,sewing Machine Lubricant Oil |
| Odour: | Nontoxic,tasteless | Stability: | No Deposition,No Delamination |
| Api: | CF-4,GL-4/GL-5 | ||
| Highlight: | Water Glycol HFC Hydraulic Fluid,HFC Hydraulic Fluid For Die Casting,ISO VG 46 Industrial Lubricant Oil |
||
Product Description
Shell Water-Glycol S2 CX 46 is a high-performance water-glycol fire-resistant hydraulic fluid classified as HFC under ISO 12922. Its fire resistance is achieved through the water content in the formulation. It is designed for heavy-industry hydraulic systems exposed to molten metal, open flame, or high temperature, such as steelmaking, die casting, and mining equipment.
- Fire resistance: water-glycol chemistry, difficult to ignite when leaked onto hot surfaces
- Corrosion protection: excellent rust and corrosion protection for system metals
- Lubrication: extreme-pressure anti-wear additives protect pumps and valves
- Material compatibility: compatible with common rubber seals and non-ferrous metals
- Temperature adaptability: fluid temperature ≤65 ℃ with good low-temperature startup
| Item | S2 CX 46 Typical | Note |
|---|---|---|
| ISO VG | 46 | — |
| Kinematic viscosity 40 ℃ | ~46 mm²/s | — |
| Water content | 42.5–44.5% | — |
| Pour point | ~-39 ℃ | — |
| Density 15 ℃ | ~1080 kg/m³ | — |
| pH | ~9.5 | — |
| Operating temperature | ≤65 ℃ | fluid temperature |
| System pressure | vane ≥2200 psi; piston ≤4000 psi | — |
| Type | HFC water-glycol | ISO 12922 |
Typical values are not per-batch COA; confirm with current PDS.
- Fire resistance: Excellent
- Corrosion protection: Excellent
- Anti-wear: Very good
- Cold start: Excellent
- Material compatibility: Very good
- High-temp stability: Medium (fluid ≤65 ℃)
- Steel: continuous caster, blast furnace, coke oven, hot rolling mill
- Die casting and foundry equipment
- Mining equipment near open flame
- Other heavy-industry hydraulics with molten metal or high-temperature risk
- Temperature: fluid temperature must not exceed 65 ℃; avoid prolonged overheating and water evaporation
- Pressure: use within vane pump ≥2200 psi and piston pump ≤4000 psi range
- Seals: compatible with common NBR-type rubber; verify seal material per equipment manual
- Not miscible with mineral oil: drain and flush before conversion
- Water monitoring: check water content regularly; replenish with dedicated conditioning fluid, never plain water
- Not for: phosphate-ester EH servo systems or synthetic-ester HFDU service
- Conversion: drain mineral oil → water-glycol compatible flush → change filters → circulate
- In service, monitor viscosity, pH, water content, and corrosion protection
- If water content is low, add dedicated conditioning fluid as recommended — never add tap water
- Store sealed, frost-free, dust-free; prevent freezing which may cause separation
The product name on this page is a model identifier for product description only. Brand references do not constitute authorization or OEM approval. Verify the equipment manual, seal compatibility, and latest PDS/SDS before purchase.
Values above are publicly available typical references, not per-batch specifications. This product is HFC water-glycol fire-resistant fluid; no third-party OEM approval claims are made.