• Anti Wear VG32 Fire Resistant Hydraulic Fluid Low Temperature For Cold Region HFC
Anti Wear VG32 Fire Resistant Hydraulic Fluid Low Temperature For Cold Region HFC

Anti Wear VG32 Fire Resistant Hydraulic Fluid Low Temperature For Cold Region HFC

Product Details:

Place of Origin: Chian
Brand Name: Great Wall
Certification: Q/SH PRD122—2012;ISO 6743-4 L-HFC;GB-T 21449
Model Number: Water-Glycol Fire-Resistant Hydraulic Fluid 32#

Payment & Shipping Terms:

Minimum Order Quantity: 10 drums
Price: Get Latest Quotation
Packaging Details: 4drums per pallet, stretch film wrapped
Delivery Time: 5-8 business days after receipt of deposit
Payment Terms: L/C,D/A,D/P,T/T
Supply Ability: Up to 50 metric tons per week
Get Best Price Chat Now

Detail Information

Oxidationstability: High Basefluid: Water Glycol / Synthetic Ester / Phosphate Ester
Flashpoint: Above 150°C Corrosionprotection: Excellent
Viscosity: ISO VG 46 / 68 / 100 Watercontent: Low
Compatibility: Compatible With Most Seals And Metals Type: Hydraulic Fluid
Environmentalimpact: Biodegradable / Low Toxicity Operatingtemperaturerange: -20°C To 120°C
Fireresistance: High Applications: Used In Steel Mills, Mining, Power Plants, And Other High Fire Risk Environments
Productname: Fire Resistant Hydraulic Fluid Foamresistance: Good
Autoignitiontemperature: Above 300°C
Highlight:

ISO VG 32 Hydraulic Fluid Systems

,

Cold Region Anti Wear Hydraulic Oil

,

Anti Wear Fire Resistant Hydraulic Fluid

Product Description

Product Overview

Great Wall L-HV 32 low temperature anti-wear hydraulic oil (Zhuoli L-HV series) is blended from highly refined, high viscosity index base stocks with anti-wear, oxidation, rust, foam, demulsibility, pour-point and seal-compatibility additives. It is classified as ISO VG32 under ISO 3448 and as L-HV under ISO 11158, positioned to GB 11118.1 L-HV.

Compared with standard L-HM32, L-HV32 adds cold-start, cold-flow and viscosity-temperature performance while retaining an anti-wear system for medium-to-high pressure circuits. VG32 is a mid-low viscosity grade with low start-up resistance and fast response, suitable for construction machinery, building and mining equipment, oilfield machinery, marine outdoor hydraulics and northern winter mobile systems.

Key Performance Benefits
  • Cold start and flow: High-VI, low-pour formula with a typical pour point of approximately −39°C, reducing pump-suction resistance and starting current in cold regions, lowering cold-start wear and cavitation.
  • High VI and shear stability: Small viscosity change across temperature — not too thick when cold, better hot-film retention — for steadier pressure in wide-temperature duty.
  • Wear reduction: Inherits HM anti-wear performance for vane, gear and piston pumps and valves; use per pump pressure approval.
  • Oxidation stability: Inhibits sludge, varnish and acid build-up; longer drain interval than standard AW oil.
  • Rust and corrosion control: Protects steel and copper parts; for silver or sensitive copper components, use a low-temperature ashless grade.
  • Demulsibility and foam control: Fast water separation and low foam tendency with good air release, reducing valve sticking and cavitation.
  • Seal compatibility: Compatible with NBR and common hydraulic elastomers to reduce leakage.
VG32 Viscosity and Low-Temperature Reference
Item L-HV32 Typical / Reference Note
ISO VG 32 ISO 3448
Kinematic viscosity 40°C 33.39 mm²/s typical; band 28.8–35.2 Distributor typical / ISO VG32 band
Kinematic viscosity 100°C Per TDS (mineral VG32 ref 5.2–5.5) Hot retention reference
Viscosity index High-VI LV type; HV32 typical 140–160+ Per batch TDS
Pour point −39°C Zhuoli L-HV32 typical
Flash point COC 231°C Zhuoli L-HV32 typical
Cleanliness NAS class 7 typical Distributor data
Copper corrosion ≤1 class per TDS Zinc type not for silver
Rust prevention Distilled water pass; seawater per formula GB/T 11143
Demulsibility 54°C Per TDS; HV reference 10–15 min GB/T 7305
Air release 50°C Per TDS; high-VI low-vis 3–5 min SH/T 0308
Foam I/II/III Per TDS; HV reference 10/0, 20/0, 10/0 GB/T 12579
FZG fail stage Per TDS; HP AW reference 12 SH/T 0306
Recommended pressure Medium/high per pump maker Vane / gear / piston
Recommended duty Outdoor, cold region, wide temp, frequent start Good above −25°C; verify below
VG32 Performance Ratings
Indicator Rating Visualization
Cold start / flow Excellent █████
Viscosity-temperature (high VI) Excellent █★★★★
Anti-wear Very good █████
Oxidation stability Very good █★★★★
Rust & corrosion Very good █★★★★
Demulsibility Very good █★★★★
Air release / foam Very good █★★★★
Shear stability Very good █★★★★
Elastomer compatibility Excellent █★★★★

Ratings are for storefront display only: █ excellent / very good. VG32 strengths are cold-region start-up, wide-temperature response and medium/high pressure anti-wear balance. For prolonged service well below −30°C, verify pump start-up viscosity or use L-HS. For silver or sensitive copper components, use low-temperature ashless L-HV.

Product Quality Specifications
Item Typical / Requirement Method
Appearance Bright, clear Visual
Kinematic viscosity 40°C 33.39 mm²/s; VG32 band 28.8–35.2 GB/T 265 / ISO 3104
Kinematic viscosity 100°C Report (ref 5.2–5.5) GB/T 265
Viscosity index High VI; per TDS GB/T 1995
Flash point COC 231°C GB/T 3536
Pour point −39°C GB/T 3535
Copper corrosion 100°C * 3h ≤1 class GB/T 5096
Rust prevention A No rust GB/T 11143
Demulsibility 54°C Per TDS (ref 10–15 min) GB/T 7305
Foam sequences I/II/III Per TDS GB/T 12579
Air release 50°C Per TDS SH/T 0308
Cleanliness NAS 7 typical ISO 4406 / NAS 1638
Four-ball wear Batch TDS / COA SH/T 0189
FZG fail stage Per TDS (HP AW ref 12) SH/T 0306
Specifications GB 11118.1 L-HV, ISO 11158 L-HV Maker spec
OEM approvals Cincinnati P68 / P70 / P69; Eaton per certified product Maker page
Applications
  • Outdoor cold-region medium/high pressure hydraulics: Excavators, loaders, cranes, rollers and pavers in winter service.
  • Mining and oilfield outdoor equipment: Pumping units, mine-truck hydraulics, underground support auxiliaries and oilfield machinery.
  • Marine and port: Deck machinery, truck-mounted cranes, outdoor power packs and wide-temperature mobile units.
  • Vehicles and mobile equipment: Northern outdoor vehicles, reefer tail lifts and snow equipment selected by pump VG32 window.
  • Wide-temperature shops: Indoor/outdoor switching, fast cold-start injection and press auxiliaries.
Limitations
  • Prolonged static service well below −30°C: L-HV32 covers most cold regions, but verify pump start-up viscosity; use L-HS22/32 if required.
  • Silver parts or OEM zinc-prohibited systems: Do not prefer zinc L-HV32; use a low-temperature ashless grade.
  • Do not mix with HM, HS or emulsion fluids; flush tank before changeover.
  • Ultra-high-pressure servo systems: List only per equipment-maker cleanliness, anti-wear chemistry and OEM approval.
Handling, Storage and Use
  • Do not mix with other brands of anti-wear oil, gear oil or turbine oil. For L-HV vs L-HM/L-HS mixtures, run compatibility and low-temperature viscosity tests first.
  • Flush tank and lines before fill; use a filtration trolley to target ISO 4406 cleanliness agreed with the pump maker.
  • Store cool and dry, away from water and dust. Supply formats include 165/170 kg drum, 200 L drum or 18/16 L pails per actual offer.
  • Before first fill, verify pump-allowed start-up viscosity, operating viscosity, minimum ambient temperature, maximum oil temperature and OEM approvals. For cold commissioning, run low-load circulation before rated pressure.

Want to Know more details about this product
I am interested in Anti Wear VG32 Fire Resistant Hydraulic Fluid Low Temperature For Cold Region HFC could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.