• ISO VG 46 Fire Resistant Hydraulic Fluid HFDU Synthetic Ester Hydraulic Oil For Steel Mill
ISO VG 46 Fire Resistant Hydraulic Fluid HFDU Synthetic Ester Hydraulic Oil For Steel Mill

ISO VG 46 Fire Resistant Hydraulic Fluid HFDU Synthetic Ester Hydraulic Oil For Steel Mill

Product Details:

Place of Origin: Chian
Brand Name: Great Wall
Certification: GB 11118.1 L-HV, ISO 11158 L-HV
Model Number: Great Wall 4642 Phosphate Ester HFDR Fire-resistant Hydraulic Fluid VG46#

Payment & Shipping Terms:

Minimum Order Quantity: 10 drums
Price: Get Latest Quotation
Packaging Details: 4drums per pallet, stretch film wrapped
Delivery Time: 5-8 business days after receipt of deposit
Payment Terms: L/C,D/A,D/P,T/T
Supply Ability: Up to 50 metric tons per week
Get Best Price Chat Now

Detail Information

Application: Industrial Lubricant,neck Mold,die,Glass Mold,parison Mold Type: Greases,Compressor Oil,Chemical,32#,gear Oil Additive
Specification: SAE,ACEA,Other,NSF,GB General Composition: Base Oil,Additives,Base Oil/additive,Yellow Oil,Special Application Oil
Product Name: Sewing Machine Oil,Industrial Heavy-duty Gear Oil 150,Jinganwang,SKALN Model 100# High Temperature Industrial Chain Lubricant Oil,Lndustry Lubricant Oil Color: Brown,Yellow,clear And Transparent,white,Transparent
Packing: 6PCS/Carton,Requirements,Customized,170KG /drum,200L Barrel Form: Liquid,Colloid,Factory-made,Semisolid
Quality: Excellent,High Rank Function: Reduce Friction,Protect Gear,Increasing Lubricity
Appearance: Oily Liquid,Transparent And Colorless Liquid,Brown Liquid,solid Lipid Usage: Lubrication And Maintain Sewing Machine And Related Equipement,machine Lubricant,Vessel,Car,fabric Embroidery
Packaging: 200 L/ Iron Drum,flexitank/drum,200KG/ Iron Drum,50 L/ Barrel,50 KG/ Barrel Volume: 4L,200 Liter,100 ML,13L
Feature: High Universality,High Flash Point Ignition Keywords: Hydraulic Oil,sewing Machine Lubricant Oil
Odour: Nontoxic,tasteless Stability: No Deposition,No Delamination
Api: CF-4,GL-4/GL-5
Highlight:

ISO VG 46 HFDU Hydraulic Oil

,

Steel Mill HFDU Fire Resistant Hydraulic Fluid

,

Non Toxic Biodegradable Hydraulic Fluid

Product Description

Product Overview

Great Wall 4632 synthetic ester fire-resistant hydraulic fluid N46 is formulated on a specifically structured synthetic ester base, enhanced with anti-oxidation, rust-prevention and lubrication additives. It is a non-toxic, biodegradable green fluid classified as HFDU under ISO 12922.

Compared with mineral HM/HV fluids, it offers a higher flash point, higher viscosity index and inherent fire resistance. Compared with phosphate ester HFDR fluids, it delivers similar lubrication performance, wider seal compatibility and lower toxicity, and can serve as a replacement for phosphate ester fire-resistant fluid. The N46 / VG46 grade is the primary choice for steel continuous casting and blast furnace hydraulics.

ISO 12922 HFDU ISO VG 46 Biodegradable VI ≥ 180
Key Performance Benefits
  • Fire resistance: High flash and fire point; passes the manifold ignition test and self-extinguishes on hot steel surfaces.
  • High viscosity index (≥180): Flat viscosity curve delivers stable pressure from cold start through hot operation.
  • Wear protection: Synthetic ester lubricity exceeds mineral oil and water-glycol for piston, gear and vane pumps.
  • Thermal stability: Shear-stable with low sludge formation and extended drain intervals.
  • Material tolerance: Compatible with most metals and elastomers after verification.
  • Biodegradable: Non-toxic with low aquatic impact compared with phosphate ester.
VG46 Viscosity and Fire-Resistance Specifications (4632 N46)
Item N46 Spec Typical Reference Note
ISO VG 46 — ISO 3448
Kinematic viscosity at 40℃ 41.4 – 50.6 mm²/s 48.52 GB/T 265
Kinematic viscosity at 100℃ ≥ 9.00 mm²/s 9.646 GB/T 265
Viscosity index ≥ 180 189 GB/T 1995
Flash point (COC) ≥ 270℃ > 330℃ GB/T 267
Fire point ≥ 300℃ — GB/T 267
Pour point Per batch TDS -48℃ Low-pour series
Acid number ≤ 3.0 mgKOH/g — GB/T 7304
Manifold ignition test Pass — SH/T 0567
Seal compatibility High-ACN NBR / FKM / PTFE; neoprene, butyl, EPDM verify — HFDU guide
Service temperature -20 to 135℃ (normal -20 to 90℃) — Great Wall 4632
Max pressure 40 MPa — Great Wall 4632
Cleanliness Filter to system requirement — —
VG46 Performance Profile
Indicator Rating Visualization
Fire resistance Very good (vs mineral) ████░
Flash / fire point Excellent █████
Viscosity-temperature (VI ≥ 180) Excellent █★★★★
Cold start Very good ████░
Anti-wear Very good █████
Oxidation stability Very good █★★★★
Biodegradability Excellent █★★★★
Seal compatibility width Wider (verify compound) ████░
Turbine EH servo Medium (not phosphate-EH) ███░░

Ratings are provided for storefront reference only. HFDU strength lies in steel-mill fire risk, wide temperature range and eco profile. It is not intended for turbine EH servo applications (use HFDR), and mineral oil must be flushed before filling.

Product Quality Items
Item Requirement Method
Appearance Clear Visual
Kinematic viscosity at 40℃ 41.4 – 50.6 mm²/s GB/T 265
Kinematic viscosity at 100℃ ≥ 9.00 mm²/s GB/T 265
Viscosity index ≥ 180 GB/T 1995
Flash point (COC) ≥ 270℃ GB/T 267
Fire point ≥ 300℃ GB/T 267
Acid number ≤ 3.0 mgKOH/g GB/T 7304
Manifold ignition Pass SH/T 0567
Specifications Q/SH PRD123—2011; ISO 12922 HFDU —
OEM approvals Wuhan Atlantic caster, CISDI material approval —
Applications
  • Steel industry: Continuous casting hydraulics, blast furnace, furnace breaker, hot rolling and ladle valve systems.
  • Power generation: High-temperature auxiliary hydraulics and waste incineration furnace systems.
  • Coal mining: Fire-risk hydraulic equipment (use MA-certified HFDU46/68 for underground applications).
  • Phosphate ester replacement: Verify compatibility and seals before changeover.
Limitations and Changeover Notes
  • Turbine EH servo: Use HFDR phosphate ester; 4632 is not designed for EH resistivity specifications.
  • Replacing mineral oil: Residual mineral oil must be below 5%; flush tank and lines and change filters.
  • Replacing water-glycol: System water content must be below 0.2%; keep water out.
  • Replacing phosphate ester or other ester: Run a compatibility test and check seals.
  • Seals: High-ACN NBR is usable after verification; FKM/PTFE preferred; neoprene, butyl and EPDM per seal manufacturer guidance.
  • Temperature: Tank temperature ≤ 60℃ preferred; the 120℃ limit is not for continuous operation.
Handling, Storage and Use
  • Do not mix with mineral HM/HV, HFC water-glycol or HFDR fluids without a compatibility check.
  • Drain old oil, flush with 4632 or an approved cleaner, and replace filter elements.
  • Store sealed, dry and dust-free; available in 4 L containers and 200 L drums (170 kg).
  • In service, monitor viscosity, acid number, water content and contamination; confirm same-brand top-up compatibility.
  • Verify the pump viscosity window and seal compound before first fill; no "OEM original replacement" claim is made.

Trademark and Fitment Disclaimer

Brand or model names on this page are fitment references only and do not constitute authorization or original-equipment replacement. This product is Great Wall 4632 HFDU synthetic ester fire-resistant hydraulic fluid.

Disclaimer: N46 specification values (viscosity 41.4 – 50.6, 100℃ ≥ 9.00, VI ≥ 180, flash ≥ 270, fire point ≥ 300, acid ≤ 3.0, manifold test pass) are drawn from public 4632 data tables. Typical values 48.52 / 9.646 / VI 189 / flash > 330 / pour -48 are N46 typical references from distributor pages and are not guaranteed per batch — confirm with SINOPEC / Great Wall COA before listing. Q/SH PRD123—2011 and HFDU positioning are from the Great Wall 4632 page; seal compatibility uses general HFDU guidance, not phosphate-ester rules.

Want to Know more details about this product
I am interested in ISO VG 46 Fire Resistant Hydraulic Fluid HFDU Synthetic Ester Hydraulic Oil For Steel Mill could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.