• ISO VG 100 Heavy Load Film Fireproof Hydraulic Fluid HFDU Oil High Viscosity Index
ISO VG 100 Heavy Load Film Fireproof Hydraulic Fluid HFDU Oil High Viscosity Index

ISO VG 100 Heavy Load Film Fireproof Hydraulic Fluid HFDU Oil High Viscosity Index

Product Details:

Place of Origin: Chian
Brand Name: Great Wall
Certification: Q/SH PRD123—2011;ISO 12922 HFDU
Model Number: Great Wall 4632 Synthetic Ester HFDU Fire-resistant Hydraulic Fluid N100 / VG100#

Payment & Shipping Terms:

Minimum Order Quantity: 10 drums
Price: Get Latest Quotation
Packaging Details: 4drums per pallet, stretch film wrapped
Delivery Time: 5-8 business days after receipt of deposit
Payment Terms: L/C,D/A,D/P,T/T
Supply Ability: Up to 50 metric tons per week
Get Best Price Chat Now

Detail Information

Product Type: Synthetic Ester Fire-Resistant Hydraulic Fluid Key Performance: High Flash Point, High Viscosity Index
Fire Resistance Class: ISO 12922 HFDU Base Oil Type: Synthetic Ester
ISO Viscosity Grade: 100 Environmental Compliance: Biodegradable, Non-Toxic
Highlight:

ISO VG 100 Fireproof Hydraulic Oil

,

Biodegradable HFDU Hydraulic Fluid

,

High Load Biodegradable HFDU Oil

Product Description

Product Description

Great Wall 4632 synthetic ester fire-resistant hydraulic fluid N100 is formulated from specifically structured synthetic esters combined with anti-oxidation, rust-prevention, and lubrication additives. It is a non-toxic, biodegradable green fluid classified as HFDU under ISO 12922.

Compared with mineral HM/HV oils, it offers a higher flash point, higher viscosity index, and inherent fire resistance. Compared with phosphate ester HFDR fluids, it delivers similar lubrication performance, wider seal compatibility, and lower toxicity, and can serve as a replacement for phosphate ester fire-resistant fluid. N100/VG100 is the highest-viscosity grade in the 4632 range — providing a thick film and low internal leakage, suited for slow heavy-duty cylinders and high-temperature actuators. It is not intended for fast servo or cold-start priority systems.

Key Performance Benefits
  • Fire resistance: High flash and fire point; passes the manifold ignition test; self-extinguishes on hot steel surfaces.
  • High viscosity index (≥180): Stable hot viscosity and steady pressure under load.
  • Heavy-load film: Synthetic ester lubricity exceeds mineral oil and water-glycol for piston pumps.
  • Thermal stability: Shear-stable with low sludge formation and longer drain intervals.
  • Material tolerance: Compatible with most metals and elastomers after verification.
  • Biodegradable: Non-toxic with low aquatic impact compared to phosphate ester.
VG100 Viscosity and Fire-Resistance Chart (4632 N100)
Item N100 Spec Typical Ref Note
ISO VG 100 — ISO 3448
Kinematic viscosity 40℃ 90~110 mm²/s Per batch COA GB/T 265
Kinematic viscosity 100℃ ≥13.00 mm²/s Per batch COA GB/T 265
Viscosity index ≥180 — GB/T 1995
Flash point COC ≥270℃ — GB/T 267
Fire point ≥300℃ — GB/T 267
Pour point Per batch TDS Low-pour series N100 exclusive not published
Acid number ≤3.0 mgKOH/g — GB/T 7304
Manifold ignition test Pass — SH/T 0567
Seal compatibility High-ACN NBR/FKM/PTFE; neoprene/EPDM/butyl verify — HFDU guide
Service temp -20~135℃ (normal -20~90℃) — Great Wall 4632
Max pressure 40 MPa — Great Wall 4632
Cleanliness Filter to system requirement — —
VG100 Performance Overview
Indicator Rating Visualization
Fire resistance Very good (vs mineral) ████░
Flash / fire point Excellent █████
Viscosity-temperature (VI≥180) Excellent █★★★★
Heavy-load film Excellent (top of range) █████
Anti-wear Very good █████
Oxidation stability Very good █★★★★
Biodegradable Excellent █★★★★
Seal compatibility width Wider (verify compound) ████░
Cold start / fast response Medium (thicker than N68) ██░░░
Turbine EH servo Low (not phosphate-EH) ██░░░
Ratings are for storefront reference only. N100's strengths are slow heavy-duty operation, thick film, and fire-risk environments; its weaknesses are cold-start viscosity and fast-action response — use N32/N46 for those applications. Not for turbine EH servo (use HFDR).
Product Quality Items
Item Requirement Method
Appearance Clear Visual
Kinematic viscosity 40℃ 90~110 mm²/s GB/T 265
Kinematic viscosity 100℃ ≥13.00 mm²/s GB/T 265
Viscosity index ≥180 GB/T 1995
Flash point COC ≥270℃ GB/T 267
Fire point ≥300℃ GB/T 267
Acid number ≤3.0 mgKOH/g GB/T 7304
Manifold ignition Pass SH/T 0567
Specs Q/SH PRD123—2011; ISO 12922 HFDU —
OEM approvals Wuhan Atlantic caster, CISDI material approval —
Applications
  • Steel industry: Caster heavy clamps and lifts, blast furnace slow hydraulics, furnace breaker main cylinder, ladle turret.
  • Metallurgy heavy-duty: Large piston-pump systems, hot-slab slow actuators, caster main cylinders.
  • Power generation: High-temperature heavy auxiliary hydraulics, waste incineration large cylinders.
  • Coal mining: Fire-risk heavy equipment (use MA-certified HFDU46/68 underground).
  • Phosphate ester replacement: Verify compatibility and seals before changeover.
Limitations
  • Fast servo / NC hydraulics: N100 cold viscosity slows response; use N32/N46 instead.
  • Turbine EH servo: Use HFDR phosphate ester; 4632 is not designed for EH resistivity specifications.
  • Cold-region outdoor prime grade: Pour point per batch TDS; prefer N32/N46 for cold start.
  • Replacing mineral oil: Residual mineral must be <5%; flush tank and lines, change filters.
  • Replacing water-glycol: System water must be <0.2%; keep water out.
  • Replacing phosphate ester / other ester: Run a compatibility test and check seals.
  • Seals: High-ACN NBR usable after verification; prefer FKM/PTFE; neoprene/EPDM/butyl per seal manufacturer guidance.
  • Metals / paint: Avoid lead/zinc/cadmium parts and zinc coatings; verify tank paint compatibility.
  • Temperature: Tank ≤60℃ preferred; normal range -20~90℃; 120℃ limit is not continuous.
Handling, Storage and Use
  • Do not mix with mineral HM/HV, HFC water-glycol, or HFDR without a compatibility check.
  • Drain old oil, flush with 4632 or an approved cleaner, and replace filter elements.
  • Store sealed, dry, and dust-free; available in 200L drums (170kg).
  • In service, check viscosity, acid number, water content, and contamination; confirm same-brand top-up compatibility.
  • Verify pump viscosity window and seal compound before first fill; no "OEM original replacement" claim is made.

Trademark and Fitment Disclaimer
Brand or model names on this page are fitment references only, not authorization or original-equipment replacement. This product is Great Wall 4632 HFDU synthetic ester fire-resistant hydraulic fluid.
Disclaimer: N100 specification values (viscosity 90–110, 100℃ ≥13.00, VI ≥180, flash ≥270, fire point ≥300, acid ≤3.0, manifold test pass) are sourced from public 4632 data tables. No N100-exclusive typical values (density / pour point / copper corrosion) are published in those tables — the typical column is listed as "per batch COA." Q/SH PRD123—2011 and HFDU positioning are from the Great Wall 4632 page; the older Q/SH303*108-2004 appears only on distributor pages and should not be used as the main standard. Seal compatibility uses general HFDU guidance, not phosphate-ester rules.

Want to Know more details about this product
I am interested in ISO VG 100 Heavy Load Film Fireproof Hydraulic Fluid HFDU Oil High Viscosity Index could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.